ar8350t5060bas

Remove/install the air conditioning's condenser fan (roof equipment)

Type ar · emne 83.50 · version 0101 · 2005-07-12

Gælder for: MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater MODELS NMB613.455 with CODE (HKB) Konvekta ACX 641 SAPTCO air conditioning without roof heater

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.50 Bagsædeklimaanlæg — Serie 613 (modeller 358, 388, 455)

EinPAS 39 Varmesystem/ventilation/køling › 39.15 Klimatisering › 39.15.30 Blæsermotor/servomotor — Serie 613 (modeller 358, 388, 455)

AR83.50-T-5060BAS

Remove/install the air conditioning's condenser fan (roof equipment)

10.2.03

MODELS NMB613.358 /388 with CODE (HKD) Konvekta ACX 640 air conditioning with roof heater

MODELS NMB613.455 with CODE (HKE) Konvekta ACX 642 air conditioning with roof heater

MODELS NMB613.455 with CODE (HKB) Konvekta ACX 641 SAPTCO air conditioning without roof heater

Remove/install the air conditioning's condenser fan (roof equipment)

T83.50-0030-11

Shown on model 613.455 with Konvekta ACX 641 SAPTCO air conditioning without roof heater code HKB

1 Condenser fan

2 Bolt

3 Electrical connector

Remove/install

Danger!

Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area.

AS65.00-Z-0002-01A

Danger!

Risk of injury caused by scraping or cutting body parts on sharp vehicle parts

Always wear protective gloves when working on or near sharp and non-deburred vehicle parts.

Deburr repair panels.

AS00.00-Z-0017-01A

1

Loosen screw (2)

2

Remove condenser fan (1) and place aside

Installation: Note installation position of condenser fan (1).

3

Separate cable strap

Installation: Use new tie straps.

4

Separate electrical connection (3)

5

Install in the reverse order

Henviste dokumenter