AR83.50-D-6700NA | Remove/install refrigerant lines in underfloor/engine compartment | 30.11.09 |
MODEL 901.67, 902.67, 903.67 with CODE (HH7) Additional air conditioning in rear
MODEL WD2, WD3, WD6, WD7 with CODE (HH7) Additional air conditioning in rear
D83.50-1121-09
1 Refrigerant line pressure side
2 Refrigerant line intake side
3 Line bracket
7 Connection plate
8 Distributor block on intake side
9 Line connection on thrust side
4 Underfloor line connection
5 Line bracket
6 Nut
| Remove/install | ||
Danger! | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | ||
1 | Park vehicle over a repair pit or on a lifting platform | ||
2 | Discharge air conditioning system | ||
3 | Detach connection plate (7) for refrigerant line (2) from distributor block (8) | Installation: Use new sealing ring. Coat sealing ring with refrigeration oil before installation. | |
| |||
| |||
4 | Disconnect line connection (9) | Installation: Use new sealing ring. Coat sealing ring with refrigeration oil before installation. | |
| |||
| |||
5 | Raise vehicle | With lifting platform. | |
6 | Disconnect line connections (4) of the refrigerant lines at the front left underfloor | Installation: Use new sealing rings. Coat sealing rings with refrigeration oil before installation. | |
| |||
| |||
| |||
7 | Detach line holder (3) of refrigerant lines at the underfloor | ||
8 | Detach damping mount (5) from the underfloor and remove from the refrigerant lines | ||
9 | Detach refrigerant lines from the underfloor | ||
10 | Install in the reverse order | ||
11 | Evacuate the air conditioning system, refill it, and then check the system to make sure that it functions correctly and does not leak. |
Rear air conditioning unit
Number | Designation | Model | Model | |
BA83.50-N-1005-01C | Line connection, thrust side refrigerant lines | Nm | 16 | 16 |
BA83.50-N-1006-01C | Line connection, intake side refrigerant lines | Nm | 30 | 30 |
BA83.50-N-1007-01C | Nut, refrigerant lines to intake side distributor block | Nm | 10 | 10 |
Detaching tool
903 589 00 63 00
Henviste dokumenter
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8330d1760a
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel
- bb0040p036200a