1 | Electrical plug contact |
2 | High pressure switch |
A83.50-0004-06
| Remove/install | ||
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | Model 690.34/63/64, 903.66 (except 903.662), 903.67 | |
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | Model 690.34/63/64, 903.66 (except 903.662), 903.67 | |
1 | Drain air conditioning system | ||
2 | Detach trim of condenser unit on roof | ||
3 | Disconnect electrical plug contacts (1) from high-pressure switch (2) | ||
4 | Remove high-pressure switch (2) | Installation: Wrap teflon tape around thread of high-pressure switch. | |
Pressure switch | |||
5 | Install in the reverse order | ||
6 | Replace air conditioning system filter drier |
Fluid reservoir |
Number | Designation | Model 690.34 | Model 690.6, 901.6, 902.6, 903.6, 904.6, 905.6 | |
BA83.30-N-1001-03A | Pressure switch | Nm | 12 | 12 |
Henviste dokumenter
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ar8330a1780b
- ar8350a5000b
- ar8350a5090b
- ar8350a5090b
- as6500z000201a Livsfare ved fald fra køretøjets tag. Fare for personskade på andre personer somfølge af nedfaldende genstande ved arbejde i tagområdet
- as8300z000101a Fare for eksplosion ved svejse- og loddearbejde på det lukkede klimaanlæg. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel