ar8330w113002a

Fill coolant circuit of stationary air conditioner

Type ar · emne 83.30 · version 0200 · 2013-01-22

Gælder for: MODEL 963 with CODE D6H (Auxiliary air-conditioning unit)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.30 Klimaanlæg — Serie 963

EinPAS 39 Varmesystem/ventilation/køling › 39.15 Klimatisering › 39.15.5 Klimaanlæg komplet — Serie 963

AR83.30-W-1130-02A

Fill coolant circuit of stationary air conditioner

MODEL

963

with CODE D6H (Auxiliary air-conditioning unit)

Modification notes

27.11.12

Installation of overflow hose at filling unit modified

Operation step 2

Stationary air conditioner

Number

Designation

MODEL 963, 964 with CODE D6H (Stationary air conditioner)

BF83.30-N-1001-02A

Coolant

Total filling capacity

Liter

2,8

Sheet

BB00.40-P-0310-01A

Sheet

BB00.40-P-0325-05A

Fill coolant circuit of stationary air conditioner
Fill coolant circuit of stationary air conditioner

963 589 00 91 00

Filling unit

000 589 54 37 00

Clamp

Fill coolant circuit of stationary air conditioner

1

Attach overflow hose (2) to expansion reservoir (1).



2

Remove cap from small opening of filling unit and firmly press overflow hose (2) into the fitting.


W83.30-1228-11

Fill coolant circuit of stationary air conditioner

3

Slide up insulation on return line (5).



4

Attach clamping device (4) to return line (5).


The return line (5) must be tightly sealed with the clamping device (4). Otherwise filling is not possible.



5

Open shut-off tap at filling unit.


The filling unit must be filled with at least 7 liters of coolant for filling the coolant circuit.
The sealing tap of the filling unit must be located min. 50 cm higher than the service valve (3).



6

Switch on coolant pump (A41 m1) with Star Diagnosis and allow it to run until bubble-free coolant is flowing out of the overflow hose (2) into the filling unit.


If after approx. 3 minutes there is still no bubble-free coolant running through the overflow hose, the return line (5) is not sealed airtight by the clamping device (4).



7

Close shut-off tap at filling unit.



8

Detach clamping device (4) from return line (5).



9

Switch off coolant pump (A41 m1) with Star Diagnosis.



10

Wait approx. 1 minute until the return line (5) has filled up.


The fluid level in the expansion reservoir (1) drops.



11

Close off return line (5) with clamping device (4).



12

Switch coolant pump (A41 m1) on again with Star Diagnosis.



13

Open shut-off tap at filling unit and wait until bubble-free coolant is flowing out of the overflow hose (2) into the filling unit.



14

Close shut-off tap at filling unit.



15

Detach clamping device (4) from return line (5).



16

Allow coolant pump (A41 m1) to run for approximately 2 more minutes. All air is removed from the coolant circuit.



17

Check the fluid level in the expansion reservoir (1). The fluid level must be level with the "max." mark. If the fluid level has dropped more than 5 mm below the "Max." mark, operation steps 11 to 16 have to be repeated again.



18

Detach clamping device (4) from return line (5)



19

Disconnect quick coupling of filling unit from service valve (3) of stationary air conditioner.



20

Fit cap onto service valve (3).



21

Detach overflow hose (2) from expansion reservoir (1).



22

Attach cap to expansion reservoir (1).


W83.30-1231-11