S83.30-A046-09
Shown on engine 622.9 |
1 | Condenser | 4 | Lock | 7 | Right air duct segment | ||
2 | Electrical connector | 5 | Lock | 8 | Left air duct segment | ||
3 | Refrigerant lines | 6 | Retaining frame | B14 | Outside temperature sensor |
S83.30-A045-79
Shown on engine 622.8 |
1 | Condenser | 5 | Lock | 8 | Left air duct segment | ||
2 | Electrical connector | 7 | Right air duct segment | B14 | Outside temperature sensor | ||
3 | Refrigerant lines |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Remove front bumper. | ||
2 | Discharge air conditioning system. |
| |
Model 447 with code HX1 (R-1234yf refrigerant) | |||
3 | Remove air duct segment (7) at right. | ||
4 | Remove air duct segment (8) at left. | ||
5 | Disconnect electrical connection (2). | ||
6 | Remove refrigerant lines (3) from condenser (1). | ||
| Condenser with connection lines modified | Model 447 with engine 622.9 | |
| Compressor oils (specification 362.1) | ||
Installation: Replace sealing rings and moisten with compressor oil. | |||
Bolt, refrigerant line to refrigerant condenser | |||
7 | Seal connection fittings on refrigerant lines (3) and on condenser (1) using suitable stop plugs. | Record plug | |
8 | Unclip outside temperature sensor (B14) and place to one side with line connected. | Do not disconnect electrical connector from outside temperature sensor (B14). | |
9 | Release left and right lock (4) and unfasten retaining frame (6). | Model 447 with engine 622.9 | |
10 | Release left and right lock (5) and remove condenser (1) downwards. | ||
11 | Remove retaining frames (6) from condenser (1). | Model 447 with engine 622.9 | |
12 | Remove refrigerant pressure sensor (B12). | When replacing condenser(1). | |
13 | Install in the reverse order. |
129 589 00 91 00
Record plug
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8330s1760e
- ar8330s1760ef
- ar8330s5435ef
- ar8820s2000e
- as0000z001701a Fare for personskade på grund af snitsår eller hudafskrabninger grundet skarpkantede køretøjsdele
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering
- bb0040p036201a