P01.10-A083-09
1a | Engine air intake duct | 1e | Bolts | 1m | Bolts | ||
1b | Cold air intake | 1f | Screw | 1n | Rivets | ||
1c | Insert fasteners | 1g | Bolts | 1o | Support | ||
1d | Bolts | 1i | Cross member |
P83.30-4932-09
3 | Plug | 8 | Drier module bracket | |
4 | Retaining ring | 9 | Drier module riser line | |
5 | Bolt M12 | 10 | Drier module filter housing | |
6 | Drier head | 11 | Desiccant bag | |
7 | Pin |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Discharge air conditioning system. | ||
2 | Remove engine air intake duct (1a). | Dismantling tool | |
3 | Remove cold air intake (1b). | Dismantling tool | |
4 | Remove insert fasteners (1c). | ||
5 | Unscrew screws (1d, 1e, 1f, 1g). | Bolt, strut to cross member | |
Bolt, lock striker to cross member/front-module carrier | |||
6 | Drill out rivets (1n). | Installation: Replace rivets (1n). | |
Commercially available devices/tools | |||
Remove drilling chips. | |||
7 | Unscrew screws (1m). | ||
8 | Remove left and right support (1o). | ||
9 | Remove crossmember (1i). | ||
10 | Remove plug (3). | Plug to condenser | |
11 | Remove circlip (4). | ||
12 | Screw M12 screw (5) into drier head (6) and pull out drier head (6). | ||
13 | Remove drier module holder (8) at pin (7) using suitable pliers. | ||
14 | Remove drier module riser line(9) together with drier module filter housing(10). | Installation: If the packaging of a new desiccant bag(11) is damaged, do not install it. | |
15 | Install in the reverse order. |
000 589 95 63 00
Dismantling tool
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8330p1760fr
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering