1 | Expansion valve |
2 | Nut |
3 | Low pressure pipe |
4 | High pressure pipe |
5 | Bolts |
P83.30-4920-06
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
Notes on handling refrigerant R1234yf | |||
| Remove/install | ||
1 | Drain air conditioning system | ||
2 | Remove windshield wiper system | ||
3 | Unscrew nut(2) | Nut, refrigerant line to expansion valve | |
4 | Remove low-pressure line (3) and high-pressure line (4) from expansion valve (1) and seal openings with suitable stop plugs | Installation: Install new sealing rings. | |
Record plug | |||
5 | Remove screws/bolts (5), remove expansion valve (1) and seal openings with suitable stop plugs | Installation: If the thread of screws/bolts (5) does not engage, remove threaded plate using extraction hook, hold in position and screw in screws/bolts (5) alternately. | |
Bolt, expansion valve to retaining plate | |||
Record plug | |||
Extraction hook | |||
6 | Install in the reverse order |
140 589 02 33 00
Extraction hook
129 589 00 91 00
Record plug
Henviste dokumenter
- ah8330n000301a Oplysninger om håndtering af kølemidlet R134a
- ah8330n000501a Klimaanlæggets kredsløb og komponenter skal beskyttes mod fugt ved reparationer
- ah8330p000302a Oplysninger om håndtering af kølemiddel R1234yf
- ar8230p6400lw Af-, påmontering af viskersystem
- ar8330p1760lwo
- as8300z000601a Fare for forgiftning ved indånding af overophedede kølemiddeldampe fra et klimaanlæg, der er påfyldt R134a. Fare for personskade ved hud- og øjenkontakt med flydende kølemiddel R134a og ved håndtering af dele, der er under tryk.
- as8300z000701a Brandfare som følge af antænding af kølemiddel R1234yf på varme dele. Fare for forgiftning ved indånding af overophedet kølemiddeldamp. Fare for personskade ved hud- og øjenkontakt med frigjort kølemiddel R1234yf og ved håndtering