ar8330l5540va

Remove/install evaporator

Type ar · emne 83.30 · version 0103 · 2011-11-21

Gælder for: MODEL 414.700 with CODE (H06) Air conditioning

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.30 Klimaanlæg — Serie 414 (modeller 700)

EinPAS 39 Varmesystem/ventilation/køling › 39.15 Klimatisering › 39.15.32 hus/varmeveksler/fordamper/filter — Serie 414 (modeller 700)

AR83.30-L-5540VA

Remove/install evaporator

15.11.11

MODEL 414.700 with CODE (H06) Air conditioning

Remove/install evaporator

L83.30-0036-09

1 Air conditioner housing top section

2 Air conditioner housing bottom section

3 Evaporator

4 Seal

5 Sealing rings

6 Retaining plate

7 Expansion valve

8 Screw

9 Preresistor group connector

10 Evaporator temperature sensor connector

11 Screw (11 each)

B10/6 Evaporator temperature sensor

R14 Series resistor group

Remove/install

1

Remove air conditioner housing

2

Remove evaporator temperature sensor (B10/6)

AR83.30-L-8085VA

3

Disconnect preresistor group connector (9)

4

Remove screws (11) around circumference of air conditioner housing.

One of the screws (11) is located below the seal on the expansion valve (7).

Carefully remove seal to allow access to screw.

5

Carefully lift air conditioner housing top section (1) and unhook linkage (arrows) of footwell air flap

6

Remove evaporator (3) from air conditioner housing bottom section (2)

Installation: Ensure correct seating of gasket (4).

When replacing evaporator (3) observe oil refilling quantity.

*BF83.55-P-1004-01A

7

Remove expansion valve (7) from evaporator (3)

Installation: Replace sealing rings (5) and moisten with compressor oil when inserting.

*BA83.30-P-1002-01A

8

Install in the reverse order

9

Replace fluid reservoir

AR83.30-P-6520GC

When replacing the receiver/drier add the prescribed amount of refrigeration oil.

*BF83.55-P-1005-01A

10

Switch on the air conditioner and allow the engine to idle for roughly 4 minutes.

Dial temperature selector wheel down to the minimum setting (blue),

blower switch to max.

11

Check air conditioning for proper operation

The air outlet temperature at the center air vent may not sink below +5 °C, or

Perform diagnosis according to Diagnosis Manual.

12

Inspect the air conditioning circuit for leaks

AR83.30-P-1209-01GC

Air conditioning system leak detector
gotis://E_83_04.0

Air conditioning

Number

Designation

Model
414.700

BA83.30-P-1002-01A

Expansion valve bolt

Nm

8

Refrigerant compressor

Number

Designation

Refrigerant
compressor 6SE12
in model 414.700

BF83.55-P-1004-01A

Additional oil filling quantity when replacing evaporator

Compressor oil

cm3

40

Specifications for Operating Fluids

Sheet

BB00.40-P-0362-00A

BF83.55-P-1005-01A

Additional oil filling capacity when replacing receiver/drier

Compressor oil

cm3

10

Specifications for Operating Fluids

Sheet

BB00.40-P-0362-00A