ar8330l1762a

Evacuating air conditioning, checking for leaks

Type ar · emne 83.30 · version 0100 · 2006-07-26

Gælder for: MODEL 667, 668, 670 with CODE (H03) Air conditioning in front section

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.30 Klimaanlæg — Serie 667 · Serie 668 · Serie 670

EinPAS 39 Varmesystem/ventilation/køling › 39.15 Klimatisering › 39.15.5 Klimaanlæg komplet — Serie 667 · Serie 668 · Serie 670

AR83.30-L-1762A

Evacuating air conditioning, checking for leaks

28.2.00

MODEL 667, 668, 670 with CODE (H03) Air conditioning in front section

Evacuating air conditioning, checking for leaks

L83.30-0002-06

Shown on model 668

1 Suction side testing and filling valve

2 Pressure side testing and filling valve

Evacuating

Danger!

Risk of explosion from welding or braizing work on closed air conditioning system. Risk of poisoning from inhaling overheated refrigerant vapors. Risk of injury from skin and eye contact with liquid refrigerant.

Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or naked flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Do not carry out repair work on the circuit of the air conditioning system unless the system is drained.

AS83.00-Z-0001-01A

1

Attach suction, treatment and filling device to testing and filling valve ( 1, 2)

*WE58.40-Z-1002-22A

2

Evacuate air conditioning system

Observe suction, treatment and filling device operating instructions.

Evacuate air conditioning system circuit until maximum possible vacuum has been reached, but for no less than 30 minutes.

Leak testing

3

Switch suction, treatment and filling device off and read off vacuum indicator

Note vacuum value, wait approx.
10 minutes and read off vacuum indicator again.

Compare difference between indicated and noted values to specified value.

*BE83.30-N-1004-04B

If vacuum drop exceeds specified value:

Examine circuit for leaks

AR83.30-D-1209-01A

If pressure drop is in specified value range:

Fill air conditioning system

AR83.30-L-1767A

4

Remove suction and pressure lines from testing and filling valves (1, 2)

*WE58.40-Z-1002-22A

Air conditioning system test values

Number

Designation

Models 667, 668, 670
with code H03

BE83.30-N-1004-04B

Permitted vacuum drop during air conditioning system leak test (10 min.)

mbar

200

Workshop equipment

WE58.40-Z-1002-22A

Air conditioning service station

Henviste dokumenter