AR83.30-D-1762A

Evacuate air conditioning system, carry out leak check

6.11.96

MODELS 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H06) Air conditioning

Evacuate air conditioning system, carry out leak check

D83.30-0004-12

Position of the testing and filling valves

1 Test and charging valve on intake side

2 Pressure side testing and filling valve

Evacuating

1

Connect intake and pressure lines of evacuation, preparation and charging unit to test and charging valve on intake (1) and pressure side (2).

*WE58.40-Z-1002-22A

2

Evacuate air conditioning system

Evacuate air conditioning circuit up to max. achievable vacuum, but for at least 30 min.

Leak test

3

Switch off evacuation, preparation and charging unit and read off vacuum pressure indication.

Note vacuum pressure value:

Wait 10 min. and read vacuum pressure display again:

Compare displayed value with noted value

Vacuum reduction > 150 mbar:

Check circuit for leaks:

AR83.30-D-1209-01A

Vacuum reduction 150 mbar:

Circuit okay:

Fill air conditioning

AR83.30-D-1767A

Workshop equipment

WE58.40-Z-1002-22A

Air conditioning service station