ar8210p401101a

Checking vacuum system of headlamp range adjustment

Type ar · emne 82.10 · version 0100 · 1999-01-11

Gælder for: MODEL 129

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 82 El-system, karrosseri › 82.10 Udvendig belysning — Serie 129

EinPAS 30 Belysningsanlæg › 30.15 Udvendig belysning › 30.15.30 Lyslængderegulering — Serie 129

AR82.10-P-4011-01A

Checking vacuum system of headlamp range adjustment

Test values for exterior lighting

Number

Designation

Model 129

BE82.10-P-1001-01D

Pressure values for pneumatic headlamp range adjustment

Position 0

mbar

400 30

Position 1

mbar

290 30

Position 2

mbar

200 30

Position 3

mbar

50 30

Checking vacuum system of headlamp range adjustment

201 589 13 21 00

Vacuum tester

Checking vacuum system of headlamp range adjustment

P82.10-2144-01

1 The pressure for the headlamp range adjustment can be measured on the pressure valve block (4). The pressure valve block (4) is located in the right component compartment.

2 Allow engine to run.

3 Set headlamp range adjustment to individual positions and read off pressure values. If the nominal value is not reached, perform leakage test.

Checking vacuum system of headlamp range adjustment

P82.10-2145-01

If the connection sockets are leaky they can be replaced by adapters (8). For this purpose separate pneumatic line (9) from control switch (7) and shorten by 50 mm. Install adapter (8) instead of cut connection socket and connect to hose connector (approx. 40 mm long).