1 | Retaining clips |
2 | Cover |
3 | Electrical connector |
4 | Mounting clip |
5 | Quick-release coupling |
6 | Central locking motor |
S80.20-4511-06
| Remove/install | ||
1 | Switch off ignition and store transmitter key outside of transmission range (min. 2 m) | ||
2 | Remove retaining clips (1) and remove cover (2) | ||
3 | Disconnect electrical connection (3) | ||
4 | Remove plug housing of electrical connector (3) from retaining clip (4) | ||
5 | Open fuel filler flap | ||
6 | Turn quick-release fastener (5) counterclockwise and remove | ||
7 | Release catch hook (arrow) and remove central locking motor (6) | ||
8 | Install in the reverse order | ||
| Check | ||
9 | Perform function check of central locking motor (6) |