P77.37-2069-09
1 Oil level marking
A Oil level
A7/5 RVC [UVS] hydraulic unit
Danger! | Risk of injury to skin or eyes caused by hydraulic fluid spraying out under high pressure. Risk of poisoning caused by swallowing hydraulic fluid. | Depressurize the hydraulic system completely before starting any work on the system. Wear protective clothing and safety glasses. | |
1 | Open and close Vario roof with Vario roof switch | The hydraulic system can be bled by opening and closing. Keep Vario roof closed after bleeding. | |
2 | Open trunk lid | ||
3 | Remove spare tire cover from trunk | ||
4 | Check oil level (A) on oil reservoir of the RVC [UVS] hydraulic unit (A7/5) | Vario roof is closed and trunk lid open. | |
5 | Correct oil level (A) on oil reservoir on the RVC [UVS] hydraulic unit (A7/5) | ||
| |||
| |||
| |||
6 | Lay spare tire cover into trunk and close trunk lid. |
Hydraulic convertible top
Number | Designation | Model | ||
BA77.37-P-1005-01A | Filler screw on hydraulic unit | Nm | 8.0 | |
Soft top hydraulic system
Number | Designation | Model | ||
BF77.37-P-1001-01A | Filling capacity | Soft top hydraulic system oil reservoir | Liters | 0.132 |
Specifications for Operating Fluids | Sheet | |||
Filler syringe
230 589 01 63 00
Henviste dokumenter
- ar7737p350101r
- as0000z001301a Fare for kvæstelser på hud og øjne på grund af sprøjtende hydraulikvæske, som erunder højt tryk. Forgiftningsfare ved indtagelse af hydralikvæske