Shown on outward swinging door, single-wing, door with 720 mm,with B.C.E. drive
1 Shut off power to door control by removing fuses.
See assignment plan on fuse box cover
2 Open swiveling door with emergency unlocking.
3 Remove cover (1).
Installation: Do not pinch hose.
4 Remove sheet metal (2).
M72.25-0009-12
5 Unscrew electric connection lines (3).
6 Connect multimeter to pressure sensor (1) and switch to resistance measurement
Multimeter should indicate infinite.
7 Manually press in door seal
Multimeter must indicate a low resistance value.
8 Adjust pressure sensor sensitivity (1) by turning white plastic screw (2) so that the multimeter indicates a low resistance value when the door seal is pressed in by hand.
Do not turn metal screw located below plastic screw (2).
9 Complete vehicle
Henviste dokumenter
as0000z001101a Fare for personskade pga. fastklemning eller knusning af fingre ved af-,
påmontering og indstillingsarbejde på motorhjelm og bagklap, døre, dæksler og
soltag.