1 | Cover |
2 | Cover |
3 | Electrical connector |
4 | Mirror base |
A67 | Inside rearview mirror |
P68.40-A002-06
Warning | Risk of injury caused by irritation of the skin, eyes and respiratory system through contact or inhalation of substances contained in the mirror lens. | Wear protective gloves and safety glasses. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Perform commissioning of garage door opener. | Model 118, 177, 247 | |
Notes on programming garage door opener transmitter unit | |||
| |||
2 | Unclip cover (1) (arrows) and remove. | Long wedge | |
3 | Unclip cover (2) from mirror base (4). | ||
4 | Release and disconnect electrical connector (3) and guide electric line out of mirror base (4) (arrow B). | If installed. | |
5 | Turn inside rearview mirror (A67) on mirror base (4) with suitable open-end wrench and remove from mirror bracket. | The mirror base (4) can be turned in both directions. | |
| Check | ||
6 | Check catch hooks of cover (1). | If damage is present, | |
| |||
Replace cover (1). | |||
7 | Check catch hooks of cover (2). | If damage is present, | |
| |||
Replace cover (2). | |||
8 | Install in the reverse order | ||
Adjust | |||
9 | Adjust inside rearview mirror (A67) to steering variant. | When replacing inside rearview mirror (A67). | |
Model 118, 177, 247 |
115 589 03 59 00
Long wedge
Henviste dokumenter
- ad0000p200006mfa
- ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund af elektrostatisk afladning
- ah6805p000201a Oplysninger om programmering af sendeenhed til garageåbner
- ar6840p000101mfa
- as6000z000801r Fare for personskade på grund af irritation af hud, øjne og luftveje (indånding)på grund af indholdstoffer i ødelagt spejlglas