P68.10-3420-06
Shown with air ducting installed
1 Cover
2 Bolts
3 Bolt
4 Electrical connector
5 Electrical connector
6 Air duct
E17/15 Right front footwell lamp
X30/6 Cockpit voltage distributor (CAN) connector
X58/17 Front interior socket
| Remove | ||
1 | Unscrew bolts (2) and bolt (3) | ||
2 | Lower cover (1) | ||
3 | Disconnect electrical connector (4) from front interior socket (X58/17) | ||
4 | Disconnect electrical connectors from cockpit voltage distributor (CAN) connector (X30/6) | ||
5 | Disconnect electrical connector (5) from right front footwell lamp (E17/15) | ||
6 | Remove air ducting (6) from mount | Lay air ducting (6) down in footwell Do not disconnect electrically | |
7 | Remove cover (1) | ||
| Install | ||
8 | Install air ducting (6) on cover (1) | ||
9 | Connect electrical connector (4) to front interior socket (X58/17) | ||
10 | Connect electrical connectors to cockpit voltage distributor (CAN) connector (X30/6) | ||
11 | Connect electrical connector (5) to right front footwell lamp (E17/15) | ||
12 | Install cover (1) | Ensure that air ducting (6) is installed correctly. | |
13 | Screw in bolts (2) and bolt (3) | Note installation position of bolt (3). |