ar6510p100007mec

Install center roof paneling

Type ar · emne 65.10 · version 0100 · 2019-04-23

Gælder for: Model 167.3 except code 413 (Automatic panoramic sliding sunroof)

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 65 Tag › 65.10 Tagplade — Serie 167 (modeller 3**)

EinPAS 35 Karrosseri/ramme/monteringsdele › 35.39 Tag › 35.39.30 tagplade/tagramme — Serie 167 (modeller 3**)

AR65.10-P-1000-07MEC

Install center roof paneling

Model

167.3

except code 413 (Automatic panoramic sliding sunroof)

Install center roof paneling

216 589 02 23 00

Set of spacer blocks

The following operation steps are shown on model 167.3 except code 414 (Sliding roof).
The higher-level service document as well as the safety information in the service document must be observed.

Install center roof paneling

1

Install center roof paneling (1), fit with set of spacer blocks and fix in place.


When removing, observe specified dimensions and positions of set of spacer blocks.



2

Drill out rivet holes in center roof paneling (1) with Ø 6.7 mm (areas A).



3

Remove center roof paneling (1).



4

Deburr rivet holes on center roof paneling (1) and body on both sides.



5

Remove drilling chips.


P65.10-A072-06

Install center roof paneling

6

Apply anti-flutter adhesive to roof frame (areas B).


Observe processing specification for relining adhesive.



7

Apply 2-component adhesive on body in cross-hatched areas (areas C).


Observe pretreatment of bonding surfaces and manufacturer's specifications for drying and processing time of 2-component adhesive.


P65.10-A073-06

Install center roof paneling

8

Apply lining adhesive to roof frame (areas D).


Observe processing specification for relining adhesive.


P65.10-A074-06

Install center roof paneling

9

Install center roof paneling (1), fit with set of spacer blocks and fix in place.


When removing, observe specified dimensions and positions of set of spacer blocks.



10

Rivet center roof paneling (1) with rivet Ø 6.5x12.5 (areas E).



11

Rivet center roof paneling (1) with rivet Ø 6.4x12 (areas F).


P65.10-A075-06

Install center roof paneling

12

Center roof paneling (1) (areas G).


P65.10-A076-06