Repair materials
Number | Designation | Order number |
BR00.45-Z-1001-07A | Zinc dust paint suitable for spot welding | A 000 986 34 42 |
BR00.45-Z-1003-13A | Blind rivet | A 003 990 98 97 |
BR00.45-Z-1004-15A | Stop plug, instrument cluster/speedometer | A 631 997 23 86 |
N64.30-2154-09
1 Install mount for side wall paneling section (1), fit and fasten with clamping pliers.
2 Drill Ø 4.0 mm rivet holes on mount for side wall paneling section (1) (areas A and C).
Drill rivet holes at a distance of approx. 40 mm (area C).
3 Remove mount for side wall paneling section (1).
4 Deburr rivet holes on mount for side wall paneling section (1).
5 Install mount for side wall paneling section (1), fit and fasten with manual temporary fasteners and clamping pliers.
6 Mount for side wall paneling section (1) (area B).
N64.30-2156-06
7 Rivet mount for side wall paneling section (1) with blind rivets (areas A and C).
N64.30-2158-01
8 Mark dimensions on side wall paneling section(1) for cavity preservation hole (area D).
9 Drill Ø 10 mm hole on side wall paneling section (1) (area D).
10 Deburr hole on side wall paneling section (1) (area D).
Plug cavity preservation hole after installing cavity preservation.
Dimensions:
X approx. 45 mm
Y approx. 25 mm