AR54.61-D-5495A | Remove/install tachograph sensor at transmission | 16.2.12 |
MODEL 901, 902, 903, 904, 905
D54.61-1115-01
8 Tachograph sensor
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect ground cable from battery | ||
| Notes on battery | ||
Danger! | Risk of death caused by vehicle slipping or toppling off of the lifting platform. | Align vehicle between the columns of the lifting platform and position the four support plates at the lifting platform support points specified by the vehicle manufacturer. | |
2 | Raise vehicle | ||
3 | Remove tachograph sensor (8) | ||
| |||
4 | Install in the reverse order |
Pulse generator
Henviste dokumenter
- ah5410p000101a Oplysninger om batterier
- ah5410p000101a
- ar5461d549501a
- as0000z001001a Livsfare, hvis køretøjet glider ned fra eller tipper på liften.
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for