Shown on model 470 with engine 699 |
1 | Nut |
2 | Ground cable |
3 | Negative terminal |
4 | Electrical connector |
B95 | Battery sensor |
S54.10-4691-06
Shown on model 470 with engine 642 |
2 | Ground cable |
4 | Electrical connector |
5 | Battery sensor |
6 | Mounting clip |
7 | Screw |
S54.10-A053-76
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
Topical note | Notes on battery | ||
| Remove/install | ||
1 | Detach ground line of on-board electrical system battery. | ||
2 | Disconnect electrical connector (4). | ||
3 | Unscrew nut (1). | Model 470, 471 with engine 699 | |
Nut, battery sensor to battery negative terminal | |||
4.1 | Remove battery sensor (B95) together with ground line (2) from negative terminal (3). | Model 470, 471 with engine 699 | |
4.2 | Unclip retaining clip (6) using a suitable tool. | Model 470, 471 with engine 642 | |
| |||
5.1 | Remove battery sensor (B95) from ground line (2). | Model 470, 471 with engine 699 | |
5.2 | Remove bolt (7) and battery sensor (5) with the ground line (2). | Model 470, 471 with engine 642 | |
The battery sensor (5) and the ground line (2) are welded together, and can only be replaced together. | |||
6 | Install in the reverse order |