Shown on model 245 |
3 | Quick-release coupling |
4 | Cover |
G1 | Battery |
P54.10-2452-04
Shown on vehicles with code (B01) ECO start/stop function |
1 | Cover |
2 | Right side trunk lining |
G1/7 | Additional battery |
P54.10-3035-06
| Remove | ||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1.1 | Remove cover (4) and remove insulation mat over battery (G1) | For checking battery (G1) except on model 169.090. | |
To remove the cover (4), turn the quick-release fastener (3) counterclockwise. | |||
1.2 | Open hood | Model 169.090 | |
To check the battery (G1) | |||
2 | Open cover (1) of right side trunk lining (2) | To check the auxiliary battery (G1/7) on vehicles with code B01 (ECO start/stop function). | |
| Check | ||
3 | Visual inspection of battery (G1) for external leakage | If leaks are found, replace battery (G1). | |
Refer to: | |||
| |||
Remove/install battery (G1) | |||
Dispose of defective battery properly and in an environmentally compatible manner. | |||
4 | Visual inspection of auxiliary battery (G1/7) for external leakage | For vehicles with CODE B01 (ECO start/stop function) | |
If leaks are found, replace auxiliary battery (G1/7). | |||
Dispose of defective battery properly and in an environmentally compatible manner. | |||
Refer to: | |||
| |||
Remove/install auxiliary battery (G1/7) | |||
| |||
5 | Check fluid level of battery (G1) | Not with absorbent glass mat battery. | |
On battery (G1) without service fill level indicator: Refill distilled water, if necessary. | |||
If the service fill level indicator is a white color, the acid level is too low: Replace battery (G1), see: | |||
| |||
Remove/install battery | |||
Dispose of defective battery properly and in an environmentally compatible manner. | |||
6 | Check battery (G1) or auxiliary battery (G1/7) | ||
Cold cranking amps | |||
Battery capacity 12 Ah | |||
Battery capacity 46 Ah | |||
Battery capacity 62 Ah | |||
Battery capacity 70 Ah VRLA/AGM | |||
Battery capacity 74 Ah | |||
7 | Reduce increased voltage after charging process | For a battery (G1) or auxiliary battery (/G17) that is disconnected from the on-board electrical system and for a "Surface voltage" message in the display of the Midtronics battery tester. | |
After removing increased voltage, check battery (G1) or auxiliary battery (G1/7) again. | |||
Commercially available devices/tools | |||
8 | Charge battery (G1) or auxiliary battery (G1/7) | With test code "Charge and check" of Midtronics battery tester/test equipment. | |
After charging, check battery (G1) or auxiliary battery (G1/7) again. | |||
| Install | ||
9.1 | Insert insulation mat and install cover (4) | After checking battery (G1) except on model 169.090. | |
9.2 | Close engine hood | After checking battery (G1) only on model 169.090. | |
10 | Close cover (1) on right side trunk lining (2) | After checking the auxiliary battery (G1/7) on vehicles with code B01 (ECO start/stop function). |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1005-01A | Battery capacity 46 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 140 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 420 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 190 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 480 |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1011-01A | Battery capacity 74 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 265 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 680 |
Henviste dokumenter
- ah5410p000101a
- ah5410p000101a Oplysninger om batterier
- ar5410p0005ak
- ar5410p0007ak
- ar5410p112901a Kontrol af batteri
- ar5410p112903a Reduktion af forøget spænding efter opladning
- ar5410p1130ak
- as5410z000101a Brand-/eksplosionsfare på grund af kortslutning og udsivende knaldgas. Forbrændingsfare/fare for personskade ved ætsning af øjne, hud og sliminder på grund af batterielektrolyt/-tåge, kortslutning og lysbuepåvirkning. Fare for