7 | Heat shield |
8 | Screw/bolt |
9 | Screw/bolts |
D49.10-1164-01
1 | Temperature sensor |
2 | Electrical connection |
3 | Oxygen sensor |
4 | Exhaust pipe |
5 | ATL |
D49.20-0001-06
| Remove/install | ||
1 | Remove air intake hose downstream of air filter | ||
2 | Remove screw/bolts (8, 9) and remove heat shield (7) from exhaust pipe (4) | Bolt, heat shield to bracket | |
Bolt, heat shield to exhaust collector pipe | |||
3 | Disconnect electrical connection (2) for temperature sensor (1) | ||
4 | Expose electrical line of temperature sensor (1) | ||
5 | Remove temperature sensor (1) from exhaust pipe (4) and take off | Installation: Apply hot lubricating paste to the thread on the temperature sensor (1). | |
Paste, hot lubrication 1 kg, DBL 6879.20 | |||
Exhaust temperature sensor to exhaust pipe | |||
6 | Install in the reverse order | ||
7 | Attach diagnostic system, clear fault memory and perform initialization of the temperature sensor (1) using a diagnostic system | When replacing the temperature sensor (1) | |
|