ar4725d0013a

Remove/install evaporator pressure regulator

Type ar · emne 47.25 · version 0101 · 2016-12-16

Gælder for: Engine 111.984 in model 902, 903, 904 with code MY9 (Liquefied Gas Technology (LGT)) For liquefied petroleum gas system

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 47 Brændstofsystem, energiforsyning drivline › 47.25 Ledninger, slanger — Serie 902 · Serie 903 · Serie 904

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.31 Servomotor/indstillingsled/blandingsregulator — Serie 902 · Serie 903 · Serie 904

EinPAS 16 Brændstof-/energiforsyning motor › 16.10 Brændstofforsyning › 16.10.13 ledning/slange/ventil — Serie 902 · Serie 903 · Serie 904

Gælder også for motorer/gearkasser: 111 984

AR47.25-D-0013A

Remove/install evaporator pressure regulator

01.12.2016

Engine

111.984 in model 902, 903, 904

with code MY9 (Liquefied Gas Technology (LGT))

For liquefied petroleum gas system

Remove/install evaporator pressure regulator

1

Gas line

2

Evaporator pressure regulator

3

Vacuum hose

4

Gas line connection

5

Cable tie

6

Electrical connection

7

Screw/bolt

8

Coolant hoses

D47.25-1108-06

Danger !

Risk of explosion due to escaping combustible gas or overheating of gas cylinders.Risk of injury caused by burns to skin and eyes. Risk of frostbite to body parts caused by escaping gas and by touching components near the valves when emptying gas cylinders. Risk of poisoning or suffocation caused by inhaling gas.

Remove any sources of ignition.
Protective clothing, safety gloves and safety glasses must always be worn.
Ensure that the work area is adequately ventilated.
When working on vehicles at ambient temperatures over 60 °C, all gas cylinders must be removed.

AS00.00-Z-0018-01A

Danger !

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Note on calculation of tightening torque when using insertion or socket tools with various effective lengths

AH00.00-P-0015-01CW

Remove/install

1

Empty lines after solenoid valve liquid phase

AR47.25-D-0019A

2

Remove gas line (1) from liquid phase solenoid valve and seal connections using suitable stop plugs

Gas line to reducer

*BA47.25-N-1006-01K

Record plug

*129589009100

3

Remove vacuum hose (3)

Vacuum hose to evaporator pressure regulator

*BA47.10-N-1012-02B

4

Remove the gas line connection (4)

Gas hose to gas filter

*BA47.25-N-1008-01K

5

Pinch off coolant hoses (8)

Clamp

*000589543700

6

Remove coolant hoses (8) from the connection fitting of the evaporator pressure regulator (2)

Catch escaping coolant with a suitable vessel.

Installation: After installing the evaporator pressure regulator (2), pour any coolant that escaped back into the coolant and heater circuit.

7

Release and disconnect electrical connection (6)

8

Remove screw/bolt (7) and remove evaporator pressure regulator (2)

9

Install in the reverse order

10

Check gas line (1), gas line connection (4) and the evaporator pressure regulator (2) for leaktightness

AR07.54-D-0002A

11

Connect and run up the liquefied petroleum gas system diagnosis function check over actual values

AD07.54-D-3050A

12

Determine the actual value (Delta P)

If the pressure (Delta P) of 1150 mbar is not reached.

Adjust the evaporator pressure regulator (2).


AR47.25-D-0013-01A

13

Perform a GAP

Compressed-gas tank, gas shutoff valve

Number

Designation

Engine 111.984

BA47.10-N-1012-02B

Vacuum hose to evaporator pressure regulator

Nm

5

Fuel lines/hoses

Number

Designation

Engine 111.984

BA47.25-N-1006-01K

Gas line to reducer

Nm

16

Fuel lines/hoses

Number

Designation

Engine 111.984

BA47.25-N-1008-01K

Gas hose to gas filter

Nm

20

Remove/install evaporator pressure regulator
Remove/install evaporator pressure regulator

129 589 00 91 00

Record plug

000 589 54 37 00

Clamp

Henviste dokumenter