Test and adjustment values for ALB controller
Number | Designation | Model 690.611/63/64, | Models 690.612/613, | ||
BE42.80-N-1002-01A | ALB controller linkage | Maximum deflection play of actuator rod | mm | 15 | 15 |
See picture | |||||
Test and adjustment values for ALB controller
Number | Designation | Model 690.612/613 | ||
BE42.80-N-1002-01A | ALB controller linkage | Maximum deflection play of actuator rod | mm | 15 |
See picture | ||||
Repair materials
Number | Designation | Order number |
BR00.45-Z-1001-06A | Long-life grease | A 000 989 63 51 11 |
D42.80-0001-01
A Check
1 Determine the maximum deflection play of the actuator rod (a) at the height of the hooking up point (6). If the specified value is exceeded, replace bearing bushings (5)
B Remove/install lever
2 Detach retainer (1).
3 Unscrew nut (4).
4 Detach lever (3).
Shown on model 903 / WD2YD141
5 Detach spring (2).
6 Remove, replace bearing bushings (5).
Installation: grease bearing bushings with long-life grease.
7 Install in the reverse order.