000 588 04 19 00
Inclination meter
Measurement of angle 4 at rear axle differential
1 | Clean dirt as well as paint and sealant residue from contact surfaces (4) on housing of rear axle differential (3). |
Remove any unevenness on surface of material using a suitable tool. |
P41.10-A008-01
2 | Position sensor (020a) on contact surfaces (4) of housing of rear axle differential (3). |
For each measurement, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
P41.10-A017-01
The meter is ready to take a measurement. The display shows the measured values.
3 | Press SAVE button. |
The device saves the values. |
Measurement values display message for angle 4: Reading, e.g. 2.68° |
P41.10-2082-01
A confirmation message appears briefly and then the meter indicates that it is ready for the next measurement (angle 5). The measurement is completed and stored in memory.
Confirmation display message |
P41.10-2076-01
4 | Remove sensor (020a) from contact surfaces (4) of housing of rear axle differential (3). |
P41.10-A017-01
5 | Protect contact surfaces (4) of housing of rear axle differential (3) from corrosion. |
P41.10-A008-01
Henviste dokumenter