Measurement of angle 2 at front half of propeller shaft
All four angles should be measured in succession without interruption. An angle that has already been measured can be measured a second time if required. To do so, with the Measurement menu displayed, press the STEP button repeatedly until the display indicates Ready to measure the relevant angle.
1 | Clean contact surface of test adapter (3) of sensor (020a) at front half of propeller shaft (1). |
2 | Position test adapter (3) vertically from below onto front half of propeller shaft (1) and align. |
3 | Place sensor (020a) from above onto test adapter (3). |
When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
The sensor (020a) must be aligned vertically with the spirit level. |
P41.10-2391-02
The value measured is shown on the display.
4 | Press SAVE button. |
The values are saved. |
Measurement values on display message for angle piece 2: Display, e.g. 2.18° |
P41.10-2078-01
A confirmation message appears briefly.
Display message confirmation |
P41.10-2076-01
5 | Remove sensor (020a) and test adapter (3) from front half of propeller shaft (1). |
P41.10-2391-02
The display then indicates that the device is ready for the next measurement (angle 3).
Ready for measurement display message for angle 3 |
P41.10-2079-01
Measurement of angle 3 at rear half of propeller shaft
6 | Clean contact surface of sensor (020a) at rear half of propeller shaft (2). |
7 | Position sensor (020a) vertically from below on rear half of propeller shaft (2) and press on firmly. |
When each measurement is taken, the side of the sensor (020a) at which the spiral cable (020b) is connected must point in the direction of travel. |
P41.10-2359-01
The value measured is shown on the display.
8 | Press SAVE button. |
The values are saved. |
Measurement values on display message for angle piece 3: Display, e.g. 2.76° |
P41.10-2080-01
A confirmation message appears briefly.
Display message confirmation |
P41.10-2076-01
The display then indicates that the device is ready for the next measurement (angle 4).
Ready for measurement display message for angle 4 |
P41.10-2081-01
9 | Remove sensor (020a) from rear half of propeller shaft (2). |
P41.10-2359-01
Henviste dokumenter
- ah4110p000201lf Oplysninger om måling af kardanaksel-knækvinkel