Check vehicle level at front and rear axles using electronic inclinometer

Type ar · emne 40.20 · version 0201 · 2019-04-19

Gælder for: Model 415

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 40 Hjul, undervognsudmåling › 40.20 Undervognsudmåling — Serie 415

EinPAS 20 Undervogn › 20.10 Undervognsudmåling › 20.10.20 diagnose/kontrol/udmåling/indstilling — Serie 415

AR40.20-S-0302C

Check vehicle level at front and rear axles using electronic inclinometer

18.04.2019

Model

415

Modification notes

16.04.2015

Method modified

Operation steps 3 to 8

Check vehicle level at front and rear axles using electronic inclinometer

Illustration shows measurement of front axle on left side of vehicle

2

Measuring plate

3

Measuring sensor connecting cable

4

Measuring sensor

6

Supporting joint

7

Transverse control arm

S40.20-4505-06

Check vehicle level at front and rear axles using electronic inclinometer

Shown is measurement on the rear axle

3

Measuring sensor connecting cable

4

Measuring sensor

S40.20-4506-06

Check

1

Observe general information on chassis alignment

AR40.20-S-0201C

Clean

2

Clean measuring points on front transverse control arms (7) and on the rear axle


The measuring points must be clean and free of residue.
Otherwise, measurement errors may occur.

3

Attach measuring plate (2) to left transverse control arm (7)

000 588 05 19 00 Vehicle level inclinometer

WS40.00-P-0007B

The measuring plate (2) is magnetic and is designed for the right and left side of the vehicle; it must be correctly positioned accordingly. Place the measuring plate (2) with the guide pins flush against the transverse control arm (7) and against the supporting joint (6) as shown.

4

Check vehicle level at front axle on basis of transverse control arm inclination

000 588 05 19 00 Vehicle level inclinometer

WS40.00-P-0007B


The connecting cable for the measurement sensor (3) must face the vehicle center.
Otherwise measurement errors will occur.

To do so, position the measurement sensor (4) on the measuring plate (2). Measure the vehicle level at measuring point 1 (left front) and store the measured values.

5

Attach measuring plate (2) to right transverse control arm (7)

000 588 05 19 00 Vehicle level inclinometer

WS40.00-P-0007B

The measuring plate (2) is magnetic and is designed for the right and left side of the vehicle; it must be correctly positioned accordingly. Place the measuring plate (2) with the guide pins flush against the transverse control arm (7) and against the supporting joint (6) as shown.

6

Check vehicle level on opposite side of vehicle at front axle on basis of transverse control arm inclination

000 588 05 19 00 Vehicle level inclinometer

WS40.00-P-0007B


The connecting cable for the measurement sensor (3) must face the vehicle center.
Otherwise measurement errors will occur.

To do so, position the measurement sensor (4) on the measuring plate (2). Measure the vehicle level at measuring point 2 (right front) and store the measured values.

7

Detach measuring plate (2)

8

Check vehicle level on left and right side of vehicle at rear axle on basis of transverse control arm inclination

000 588 05 19 00 Vehicle level inclinometer

WS40.00-P-0007B


The measurement sensor connecting cable (3) must face forward. Place the measurement sensor (4) in the same position on the right and left side of vehicle.
Otherwise measurement errors will occur.

As far as possible, place the measurement sensor (4) centrally on the rear axle in the direction of the wheel, as shown. Measure vehicle level at Measuring point 3 (left front) and measuring point 4 (right front) and store measured values.

9

Apply underfloor protection to the pre- cleaned surfaces on the rear axle

Topical note

Instructions for processing permanent underbody protection

AH97.20-P-9409-01A

Underfloor protection 800 ml

*BR00.45-Z-1001-05A

Repair materials

Number

Designation

Order number

BR00.45-Z-1001-05A

Underfloor protection 800 ml

A 001 986 46 10

Henviste dokumenter