AR28.19-W-1006A | Remove/install speed sensor | 24.11.08 |
TRANSFER CASE 750.55 in MODEL 970.###, 972.###, 976.### ## up to 501091
TRANSFER CASE 750.81 in MODEL 976.### ## up to 501091
TRANSFER CASE 750.70 in MODEL 950.###, 952.### ## up to 501091
TRANSFER CASE 750.81 in MODEL 952.5## ## up to 501091
TRANSFER CASE 750.85 in MODEL 930.###, 932.###, 934.###, 950.###, 952.###, 954.### ## up to 501091
TRANSFER CASE 750.86 in MODEL 930.###, 932.###, 934.###, 950.###, 952.###, 954.### ## up to 501091
W28.19-0004-01
Shown on transfer case 750.55
1 Plug connection
B17 Speed sensor
| Remove/install | ||
1 | Disconnect electrical connector (1) from speed sensor (B17) | Installation: Attach tamper-proof seal to the electrical connector (1) with speed sensor (B17). | |
2 | Unscrew speed sensor (B17) | | |
3 | Install in the reverse order |
Transfer case electrical system
Number | Designation | Transfer case 750.552/554 | Transfer case 750.704/705 | Transfer case 750.816/817/818 | ||
BA28.19-N-1002-01D | Speed sensor to transfer case | Nm | 40 | 40 | 40 | |
Transfer case electrical system