000 589 88 33 00
Puller, two-arm
176 589 00 40 00
Counterholder
126 589 02 09 00
Socket wrench bit
Remove output flange (1)
1 | Screw 2 bolts into output flange (2). |
2 | Counterhold output flange (1) with counterholder at 2 bolts. |
3 | Unscrew twelve-point collar nut (2) using socket wrench socket from output shaft (3). |
Example illustration
P27.50-2077-12
4 | Remove output flange (1). |
If output flange (1) is stuck use two-armed puller (08). |
Example illustration
P27.50-2078-11
Install output flange (1)
5 | Slide output flange (1) onto output shaft (3). |
6 | Counterhold output flange (1) using counterholder on 2 bolts and tighten twelve-point collar nut (2) using socket wrench socket . |
Replace twelve-point collar nut (2). |
Example illustration |
P27.50-2077-12
7 | Secure twelve-point collar nut (2); to do so, pound collar into grooves of output shaft (3) using a punch (arrow). |
There are two grooves located on the output shaft (3), into which the collar of the twelve-point nut (2) must be pounded (arrow). |
8 | Remove 2 bolts from output flange (1). |
Example illustration
P27.50-2079-11