1 | Hydraulic pump |
2 | Nut |
3 | Seal |
4 | Adapter |
W26.45-0064-11
Warning | Risk of injury to skin or eyes from hydraulic fluid spraying out under pressure.Risk of poisoning from swallowing hydraulic fluid. | Depressurize hydraulic system completely before starting any work on it. Wear protective clothing and safety glasses. | |
Caution | Risk of injury to skin and eyes due to handling of transmission oil. Health risk caused by swallowing transmission oil | Wear protective gloves, protective clothing and safety glasses. | |
| Remove/install | ||
1 | Disconnect hydraulic lines from hydraulic pump (1). | Collect hydraulic fluid which flows out in a suitable vessel. | |
2 | Remove hydraulic pump (1) and adapter (4). | Collect escaping hydraulic fluid or transmission oil with suitable containers. | |
Installation: Clean sealing surfaces and replace seals (3). | |||
Nut, hydraulic pump to power take-off | |||
3 | Install in the reverse order. | ||
| Check | ||
4 | Check hydraulic fluid level in oil container; correct if necessary. | See operator's manual and maintenance procedures of the body manufacturer. | |
5 | Check transmission oil level, correct, if necessary. | ||
|