ar2520a0070i

Bleed clutch operating system

Type ar · emne 25.20 · version 0100 · 2006-07-26

Gælder for: MODEL 374.602 /651 with TRANSMISSION 710.550 /551 /552 /553 /554 /555 /556 MODEL 374.602 /651 /655 /682 /685 with TRANSMISSION 710.560 /561 /562 /563 /564 /565 /566 /570 /571 /572 /573 /574 /575 /576

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 25 Kobling › 25.20 Koblingsbetjening — Serie 374 (modeller 602, 651, 655, 682, 685)

EinPAS 17 Drivstreng/aksel › 17.15 Kobling › 17.15.5 koblingsbetjening — Serie 374 (modeller 602, 651, 655, 682, 685)

Gælder også for motorer/gearkasser: 710 550, 710 551, 710 552, 710 553, 710 554, 710 555, 710 556, 710 560, 710 561, 710 562, 710 563, 710 564, 710 565, 710 566, 710 570, 710 571, 710 572, 710 573, 710 574, 710 575, 710 576

AR25.20-A-0070I

Bleed clutch operating system

21.6.06

MODEL 374.602 /651 with TRANSMISSION 710.550 /551 /552 /553 /554 /555 /556

MODEL 374.602 /651 /655 /682 /685 with TRANSMISSION 710.560 /561 /562 /563 /564 /565 /566 /570 /571 /572 /573 /574 /575 /576

Bleed clutch operating system

A25.20-0003-06

1 Connection line (bleeder unit)

2 Expansion reservoir

3 Bleed valve

4 Clutch servo assistance

5 Venting hose

Bleeding

Notes on hydraulic fluid as per Specification, Sheet 345.0

AH00.40-N-0002-01A

1

Open maintenance flap

2

Unscrew the screw cap from the expansion reservoir (2)

3

Check the level of the hydraulic fluid in the expansion reservoir (2) and replenish hydraulic fluid if necessary

Hydraulic fluids (Specification 345.0)

BB00.40-P-0345-00A

4

Connect the connection line (1) of the bleeder unit in place of the screw cap on the expansion reservoir (2)

*WH58.30-Z-1007-24A

5

Switch on bleeder unit and build up bleed pressure

See equipment manufacturer's operating instructions.

6

Connect bleed hose (5) to the bleed valve (3) of the clutch booster (4)

7

Open bleed valve (3) and leave open until the hydraulic fluid escapes free from bubbles

Collect escaping hydraulic fluid in a suitable container.

8

Detach bleed hose (5) from bleed valve (3)

9

Switch off bleeder unit and detach connection line (1) from expansion reservoir (2)

See equipment manufacturer's operating instructions.

10

Check the level of the hydraulic fluid in the expansion reservoir (2) and replenish hydraulic fluid if necessary

Hydraulic fluids (Specification 345.0)

BB00.40-P-0345-00A

11

Seal expansion reservoir (2) with screw cap

12

Check clutch for proper operation and repeat the bleeding process if necessary

13

Close maintenance flap

Commercially available tools

Number

Designation

WH58.30-Z-1007-24A

Filling and bleeder unit for hydraulic fluid (as per sheet 345.0)

Henviste dokumenter