Serier
da
ar2010w129002j
Remove/install connection piece of coolant pump to cylinder head
Type ar · emne 20.10 · version 0204 · 2010-11-29
Gælder for: ENGINE 900.9 in MODEL 375.1, 970, 972, 975, 976 ENGINE 902.9 in MODEL 375.3, 950.5 /6, 952.5 /6, 953.6, 954.5 ENGINE 902.9 in MODEL 957 except CODE (MS8) Natural gas engine ENGINE 902.9 in MODEL 375.1, 970, 972, 974, 975, 976 ENGINE 924.9 in MODEL 958.0, 970, 972, 974, 975, 976 ENGINE 925.9 in MODEL 970, 972, 974 ENGINE 926.9 in MODEL 950.5 /6, 952.5 /6, 953.6, 954.5, 957, 958.2 ENGINE 926.9 in MODEL 958.0
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 1 Motor › 20 Motorkøling › 20.10 Kølevæskepumpe, kølevæsketermostat — Serie 375 (modeller 1**, 3**) · Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 950 (modeller 5**, 6**) · Serie 952 (modeller 5**, 6**) · Serie 953 (modeller 6**) · Serie 954 (modeller 5**) · Serie 957 · Serie 958 (modeller 0**, 2**) · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976
EinPAS 15 Motor › 15.25 Motorkølesystem › 15.25.30 pumpe/termostat/forvarmningsapparat — Serie 375 (modeller 1**, 3**) · Serie 900 (modeller 9**) · Serie 902 (modeller 9**) · Serie 950 (modeller 5**, 6**) · Serie 952 (modeller 5**, 6**) · Serie 953 (modeller 6**) · Serie 954 (modeller 5**) · Serie 957 · Serie 958 (modeller 0**, 2**) · Serie 970 · Serie 972 · Serie 974 · Serie 975 · Serie 976
Gælder også for motorer/gearkasser: 924 9**, 925 9**, 926 9**
AR20.10-W-1290-02J
Remove/install connection piece of coolant pump to cylinder head
Coolant pump, coolant thermostat
Number
Designation
Engines 900.9, 902.9, 904.9, 906.9
Engine 924.9, 925.9, 926.9
BA20.10-N-1003-01C
Bolt, connection piece of coolant pump to cylinder head
Nm
50
50
Number
Designation
Order number
BR00.45-Z-1001-06A
Long-life grease
A 000 989 63 51 11
Shown on engine 926.9
1 Disconnect electrical connector (6).
2 Detach coolant hose (4) at connection piece (1).
3 Remove connection fitting (2). Installation: Replace sealing ring.
4 Unscrew bolts (3) and take off crankcase ventilation line (5).
5 Pull connecting piece (1) upwards and out of connection fitting. Installation: Install new seal and connection fitting. Grease connection fitting. Tighten bolts (3).
6 Install in the reverse order.