1 | Tensioning device |
2 | Screw |
3 | Screw |
D13.20-A003-76
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
| Remove/install | ||
1 | Remove poly-V-belt from the tensioner pulley of the clamping device (1). | ||
Installation: | |||
2 | Remove tensioning device (1). | To do so, remove screw/bolts (2, 3). | |
Screw, refrigerant compressor poly-V-belt clamping device to oil pan | |||
Screw, refrigerant compressor poly-V-belt clamping device to major assembly carrier | |||
3 | Install in the reverse order. |
Henviste dokumenter
- ar1321d0161tsv
- as0000z000201a Fare for personskade på hud og øjne ved håndtering af varme eller glødende genstande
- as0000z001701a Fare for personskade på grund af snitsår eller hudafskrabninger grundet skarpkantede køretøjsdele