P09.00-2056-07
1 Hose
2 Centrifuge cover
3 Retaining clamp
4 Air duct housing
B2/5 Hot film mass air flow sensor
M16/6 Throttle valve actuator
A CLIC clamp
4a Notch
4b Notch
5 Gasket
| Remove/install | ||
| Notes on avoiding damage through contamination and foreign objects | ||
1 | Remove air filter housing | ||
2 | Remove hot film mass air flow sensor (B2/5) | ||
3 | Detach hose (1) at centrifuge cover (2) | ||
4 | Detach retaining clamp (3) on electric wiring harness from air duct housing (4) | ||
5 | Push notch (4a) downwards and swing away air duct housing (4) below from throttle valve actuator (M16/6) | ||
6 | Raise notch (4b) and remove air duct housing (4) from throttle valve actuator (M16/6) | ||
7 | Detach hose (1) at air duct housing (4) | Only when replacing air duct housing (4) | |
8 | Check seals (5) and replace if necessary | ||
9 | Install in the reverse order |