Change data record, software, parameters in engine control (MR) control unit

Type ar · emne 07.15 · version 0101 · 2011-07-12

Gælder for: ENGINES 900.92, 902.93, 924.93, 926.95 /97, 541.95 in MODEL 000.001 with BlueTec®, parameterization with MiniDiag'

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.15 Dieselindsprøjtningssystem (PLD), motorregulering (MR) — Serie 000 (modeller 001) · Serie 900 (modeller 92*) · Serie 902 (modeller 93*)

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.11 Styreenhed/relæ — Serie 000 (modeller 001) · Serie 900 (modeller 92*) · Serie 902 (modeller 93*)

Gælder også for motorer/gearkasser: 541 95*, 924 93*, 926 95*, 926 97*

AR07.15-G-3000DE

Change data record, software, parameters in engine control (MR) control unit

20.6.11

ENGINES 900.92, 902.93, 924.93, 926.95 /97, 541.95 in MODEL 000.001
with BlueTec®,
parameterization with MiniDiag

Parameterize

1

Connect MiniDiag

Observe operator's manual for MiniDiag.

2

Switch on ignition

During parameterization, do not

Perform on-board diagnosis,

Run or start the engine and

the battery for power supply must not be clamped off.

3

Select "Automatic control unit recognition"

4

Select "KWP2000: IES/J1939"

5

Select "MR"

6

Select "Parameterization"

7

Select "Read or alter parameter from control unit "

8

Select "Proportional valves (PV)"

9

Select Proportional valve "PV1"

10

Switch actuation for "diffuser heater" on or off

To activate: actuate button "4" and then "OK" on the operating panel of MiniDiag.

To deactivate: actuate button "0" and then "OK" on the operating panel of MiniDiag.

11

Actuate back key on MiniDiag until the note "Switch off circuit 15" appears

The instructions in the MiniDiag should be observed during switching off and switching on of the ignition.

The altered parameter should be stored permanently during switching off and switching on of the ignition.

After switching on of the ignition the parameter should be checked for the "diffuser heater"; repeat the process for parameterizing if necessary.

12

Detach MiniDiag