ar0715g3000dd

Change data record, software, parameters in engine control (MR) control unit

Type ar · emne 07.15 · version 0102 · 2019-10-04

Gælder for: Engine 541.95, 900.92, 902.93, 924.93, 926.95/97 in model 000.001 with BlueTec Engine 925.9 in model 000.001 with BlueTec

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.15 Dieselindsprøjtningssystem (PLD), motorregulering (MR) — Serie 000 (modeller 001) · Serie 900 (modeller 92*) · Serie 902 (modeller 93*)

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.11 Styreenhed/relæ — Serie 000 (modeller 001) · Serie 900 (modeller 92*) · Serie 902 (modeller 93*)

Gælder også for motorer/gearkasser: 541 95*, 924 93*, 925 9**, 926 95*, 926 97*

AR07.15-G-3000DD

Change data record, software, parameters in engine control (MR) control unit

21.08.2019

Engine

541.95, 900.92, 902.93, 924.93, 926.95/97 in model 000.001

with BlueTec

Engine

925.9 in model 000.001

with BlueTec

Modification notes

21.08.2019

Document completely revised.

Programming

1

Connect diagnostic system.

It is absolutely essential to precisely follow the operation steps as described in the diagnostic system. Ensure an adequate power supply from the batteries (greater than 24 V).

See information from body manufacturer.
During programming:
- do not start any other programs,
- no European On-Board Diagnostics may run,
- the engine must not run and must not be started,
- the starter battery must not be disconnected.

2

Switch on ignition.

See information from body manufacturer.

3

Start diagnostic system.

Then Industrial engines  Direct link for control units  Engine control  Control unit adaptations  Parameterization  Peripheral parameters  Diffuser heater  Select and confirm proportional valve 1.

4

Switch ignition off and on again

When the diagnostic system requests it.

5

Confirm "Transfer central data memory" using the F3 button.

6

Disconnect diagnostic system.

See information from body manufacturer.