1 | Electrical connector |
2 | Oxygen sensor upstream of catalytic converter |
S07.04-4715-06
Warning | Risk of burn injuries, suffocation and poisoning when working on the exhaust system and the components connected to it. Risk of suffocation and risk of poisoning caused by inhalation of gaseous and solid components of the exhaust. Risk of poisoning caused by skin contact with solid components of the exhaust. | Wear protective clothing and safety glasses. Use the extraction system. Move people out of the hazard area. | |
Warning | Risk of injury. Skin or eye injuries may result when handling hot or glowing objects. | Wear protective gloves, protective clothing and safety glasses, if necessary. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Disconnect electrical connection (1) | ||
2 | Remove lambda sensor upstream of catalytic converter (2) and close off threaded hole in the catalytic converter using suitable stop plug | Installation: Apply heat-resistant lubricating paste to threads of lambda sensor upstream of catalytic converter (2). | |
Paste, hot lubrication 1 kg, DBL 6879.20 | |||
Oxygen sensor upstream of catalytic converter to exhaust manifold | |||
Socket | |||
Record plug | |||
3 | Cover sensor tip of lambda sensor upstream of catalytic converter (2) with a clean protective cover | When reusing the lambda sensor upstream of catalytic converter (2). | |
Set of protective caps | |||
4 | Install in the reverse order | ||
| Check | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
5 | Check leaktightness of exhaust system when engine is running | Visual inspection only. |
111 589 03 09 00
Socket
001 589 00 91 00
Set of protective caps
129 589 00 91 00
Record plug
Henviste dokumenter
- ah0000p500001a Oplysninger om forebyggelse af skader på grund af snavs og fremmedlegemer
- as0000z000201a Fare for personskade på hud og øjne ved håndtering af varme eller glødende genstande
- as0000z000501a Fare for ulykke ved automatisk igangsætning når motoren kører. Fare for personskade på grund af knusning og forbrænding, hvis der arbejdes mens motoren startes eller kører
- as4900z000101a Forbrændings-, kvælnings- og forgiftningsfare ved arbejde på udstødningssystemet og dermed forbundne komponenter. Kvælningsfare og fare for forgiftning ved indånding af gasformede og faste komponenter i forbrændingsgassen. Fare for