ar0703g6833ch

Clean nozzle holder combination

Type ar · emne 07.03 · version 0106 · 2018-12-06

Gælder for: Engine 457.9, 458.9 in model 000.001

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.03 Indsprøjtningsdyser, indsprøjtningsventiler, ledninger — Serie 000 (modeller 001)

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.42 brændstoffordeler/rail/dyse/injektor — Serie 000 (modeller 001)

Gælder også for motorer/gearkasser: 457 9**, 458 9**

AR07.03-G-6833CH

Clean nozzle holder combination

02.10.2018

Engine

457.9, 458.9 in model 000.001

Clean nozzle holder combination

1

Nozzle holder combination

2

Ultrasound nozzle cleaning equipment

3

Perforated cover

W07.03-1011-02

Danger

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.

No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only.
Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Topical note

Notes on avoiding damage through contamination and foreign objects

AH00.00-N-5000-01H

Clean

1

Remove nozzle holder assembly (1).

AR07.03-G-6831CH

2

Fill ultrasound nozzle cleaning equipment (2) with cleaning fluid and heat up to 60 °C.

Pay attention to operator's manual from equipment manufacturer.
Dilute cleaner in a ratio of 1:2 with water (0.5 l cleaner and 1.0 l water).
Fill tray up to marking (filling capacity approx. 1.5 l).

Cleaner, P3 Neuproton 5032

*BR00.45-Z-1033-04A

3

Insert perforated cover (3) into the ultrasound nozzle cleaning equipment (2), place nozzle holder assembly (1) vertically in the perforated cover (3), and switch on ultrasound nozzle cleaning equipment (2).

Observe safety information in the operator's manual of the equipment manufacturer.

4

Install nozzle holder assembly (1).

AR07.03-G-6831CH


After cleaning, the nozzle holder assembly (1) must immediately (after a maximum of 4 h) be reinstalled in the same engine.
Otherwise, the nozzle holder assembly (1) may become inoperable due to corrosion (jammed nozzle needle). As a result, engine damage can occur when starting the engine.

5

Start engine and bleed fuel system.

Run engine for approx. 1 min. The fuel system is ventilated automatically.

If engine fails to start or only runs for a brief period,

Bleed fuel system.


AR47.00-G-1720CI

6

Switch off engine.

Repair materials

Number

Designation

Order number

BR00.45-Z-1033-04A

Cleaner, P3 Neuproton 5032

Bandelin Elektronic GmbH & Co. KG
3-4
12207 Berlin
Germany
Tel.: +49 30 768800
Fax +49 30 77346 99
http://www.bandelin.com

Henviste dokumenter