ar0703g671201mt

Checking ejection pressure of injection nozzle

Type ar · emne 07.03 · version 0102 · 2012-05-30

Gælder for: MODEL 000.001 with ENGINE 447.903 Euro 2 MODEL 000.001 with ENGINE 444.901 Euro 2 MODEL 000.001 with ENGINE 444.901 Euro 1

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.03 Indsprøjtningsdyser, indsprøjtningsventiler, ledninger — Serie 000 (modeller 001) · Serie 444 (modeller 901) · Serie 447 (modeller 903)

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.42 brændstoffordeler/rail/dyse/injektor — Serie 000 (modeller 001) · Serie 444 (modeller 901) · Serie 447 (modeller 903)

AR07.03-G-6712-01MT

Checking ejection pressure of injection nozzle

Danger !

Risk of explosion caused by test oil being ignited. Risk of injury to skin and eyes caused by test oil streaming out

Keep all ignition sources out of the hazard area. Only check injection nozzles in the nozzle testing device. Do not touch the injection nozzle stream.

AS07.03-Z-0001-01A

MODEL

000.001 with ENGINE 447.903

Euro 2

MODEL

000.001 with ENGINE 444.901

Euro 2

MODEL

000.001 with ENGINE 444.901

Euro 1

Check values for injection nozzles

Number

Designation

ENGINE 447.903

Engine 444.901 Euro 1

BE07.03-N-1002-01L

Pressure difference within the engine

bar

10

10

Check values for injection nozzles

Number

Designation

Engine 444.901 Euro 2

BE07.03-N-1002-01L

Pressure difference within the engine

bar

10

Check values for injection nozzles

Number

Designation

ENGINE 447.903

Engine 444.901 Euro 1

BE07.03-N-1001-01L

Opening pressure of the nozzle holder combination

New

bar

220

200...210

worn

bar

200...220

180...200

Check values for injection nozzles

Number

Designation

Engine 444.901 Euro 2

BE07.03-N-1001-01L

Opening pressure of the nozzle holder combination

New

bar

220...228

worn

bar

200...220

Checking ejection pressure of injection nozzle

000 589 14 27 00

Tester

1

Check opening and ejection pressure of injection nozzle

For an adjusted pressure gauge only raise the pressure slowly and, above all, only drain slowly.
The manometer may become damaged otherwise.

Manual pump lever from test equipment Press slowly downwards for a switched-in pressure gauge (one stroke per second)and read off the opening pressure when opening (beginning of nozzle ejection).

If ejection pressure is too high or too low, the injection nozzle must be disassembled, cleaned and correctly adjusted. In the case of an excessively high pressure, the shims must be replaced by thinner ones, and for an excessively low pressure the shims must be replaced thicker ones.

Henviste dokumenter