1 | Fuel cell cover |
P06.00-2049-05
2 | Bolts |
3 | Electrical connectors |
N116/2 | Fuel cell control unit |
P06.20-2040-06
4 | Seal |
P06.20-2041-06
Danger | Risk of explosion caused by escaping hydrogen or overheating of the fuel tanks when working on the hydrogen system. Risk of frostbite to body parts caused by escaping gas and by touching component parts carrying gas when emptying fuel tanks. Risk of asphyxiation caused by inhalation of air diluted by hydrogen. Risk of burn injuries by coming into contact with an invisible pale blue hydrogen flame. | ||
Topical note | Notes on fuel cell system | ||
Topical note | Information on preventing damage to electronic components due to electrostatic discharge | ||
| Remove/install | ||
1 | Ensure that the requirements for driving into the workshop are fulfilled. | ||
Topical note | Requirements for driving into the workshop | ||
2 | Print out "tank system, fuel cell, form event log," fill out, and attach to the vehicle somewhere clearly visible. | * For Germany only | |
| |||
| Tank system event log, fuel cell, form | ||
3 | Perform commissioning of fuel cell control unit (N116/2). | When replacing fuel cell control unit (N116/2). | |
| |||
4 | Switch off ignition and store transmitter key outside of transmitter range (min. 2 m). | ||
5 | Remove fuel cell cover (1). | ||
6 | Unscrew bolts (2). | ||
7 | Disconnect electrical connection (3). | Installation: Ensure control unit pins are correctly seated. | |
8 | Remove fuel cell control unit (N116/2). | ||
9 | Check seal (4) for damage and that it is correctly seated. | If there is a problem, | |
| |||
Replace and/or correctly position seal (4). | |||
10 | Install in the reverse order. |
Henviste dokumenter
- ad0000p200004b
- ah0000p002101rfw Betingelser for indkørsel til værkstedet
- ah0000p002201rfw Oplysninger om brændselscellesystem
- ah5400p000101a Oplysninger med henblik på at undgå skader på elektroniske komponenter på grund af elektrostatisk afladning
- as0000z003001b Fare for eksplosion som følge af udstrømmende brint eller overophedning af brændstoftanke under arbejde på brintanlægget. Fare for forfrysninger på legemsdele som følge af udstrømmende gas og som følge af berøring af gasførende
- of0000p300021rfw Protokol tanksystem, brændselscelle, formular