Test and adjustment values for valve guides
Number | Designation | Engine | |||
BE05.30-N-1002-02O | Valve seat to valve guide center offset | mm | 0.02 | ||
BE05.30-N-1003-02O | Valve seat concentricity relative to valve guide | mm | 0.04 | ||
366 589 00 69 00
Valve seat turning kit
W05.30-0026-01
1 Slip clamping ring (1) over installed valve turning device pilot and tighten.
2 Fit testing unit (2) onto clamp ring (1).
3 Set feeler gauge on testing unit (2) preloaded onto the center of the valve seat.
Slowly turn testing unit (2) around pilot and inspect variation of radial runout of the valve seat to valve guide. Refer to check values.
4 Remove testing unit (2), clamp ring (1) and pilot.