Shown on engine 607 |
1 | Crankshaft gear |
2 | Radial shaft sealing ring |
S03.20-4510-05
Caution | Risk of injury to skin and eyes due to handling of engine oil. Risk of poisoning caused by swallowing engine oil | Wear protective gloves, protective clothing and safety glasses. | |
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
| Remove/install | ||
1 | Remove toothed belt. |
| |
Model 415 with engine 608 | |||
2 | Remove crankshaft gear (1). | ||
3 | Remove radial shaft sealing ring (2). | | |
Installation: Check crankshaft for galling. | |||
Installation: Install radial shaft sealing ring (2) flush in front end cover. | |||
If galling is present at crankshaft | |||
| |||
Install radial shaft sealing ring (2) evenly approx 0.7 mm deeper. | |||
Adapter | |||
Puller | |||
Insertion tool | |||
4 | Install in the reverse order. | ||
| Check | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
5 | Check for leaktightness when engine is running. | Visual inspection only. |
607 589 02 43 00
Puller
607 589 03 43 00
Insertion tool
607 589 00 43 00
Adapter