201 589 00 99 00
Electrical connection set
Compression recorder
001 589 76 21 00
P01.10-2297-01
1 Open cover (1) of battery fuse box (F31).
2 Connect clamp (A) of compression recorder to battery fuse box (F31):
P01.10-2298-01
3 Open cover of module box.
4 Detach separation point of control module box/engine (X35/63).
5 Connect adapter cable (01) to pin 6 of separation point of control module box/engine (X35/63).
6 Connect adapter cable (01) to cable of compression recorder.