ap4260m4381a

Compressed air drier - replace granulate cartridges

Type ap · emne 42.60 · version 0101 · 2006-10-31

Gælder for: MODEL 904.663 Minibus Sprinter low floor, with rear air suspension MODEL 905.613 Minibus Sprinter low floor 6 t

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 42 Bremsehydraulik og -mekanik › 42.60 Pneumatik — Serie 904 (modeller 663) · Serie 905 (modeller 613)

EinPAS 21 bremser/vakuumsystem/trykluftsystem › 21.35 trykluftsystem › 21.35.30 tørring/regulering/rengøring — Serie 904 (modeller 663) · Serie 905 (modeller 613)

AP42.60-M-4381A

Compressed air drier - replace granulate cartridges

12.10.04

MODEL 904.663
Minibus Sprinter low floor,
with rear air suspension

MODEL 905.613
Minibus Sprinter low floor 6 t

Compressed air drier - replace granulate cartridges

M42.60-0020-08

Air compressor system for parking brake

1 Granulate cartridge

Compressed air drier - replace granulate cartridges

M42.60-0019-08

Air compressor system for air-sprung rear axle

2 Rubber sealing ring

1 Granulate cartridge

Remove

1.1

Bleed compressed air drier by filling up the compressed-air system

Fill compressed-air system up to the cut off point of the pressure regulator.

1.2

Bleed the compressed air drier by releasing the compressed air

Loosen line at connection "1" of the compressed air drier, release compressed air, tighten the line again.

2

Loosen the granulate cartridge (1) using the Universal strap wrench and unscrew

Due to the oil residues deposited the granulate cartridges which have been removed are to be handled like special wastes and like oil filters.

*WH58.30-Z-1075-06A

3

Remove rubber sealing ring (2) on the threaded spigot

No sealing ring is installed on the compressed air drier of the electrical air compressor system for the parking brake.

Install

4

Grease new rubber sealing ring (2) slightly and pull on.

*BR00.45-Z-1014-06A

5

Grease seal (arrow) of new granulate cartridge as well as threaded spigot lightly.

*BR00.45-Z-1014-06A

6

Screw on granulate cartridge (1) by hand until the sealing ring abuts the housing then tighten with a further half turn.

7

Ventilate compressed air drier and check for leaks

Testing is only possible up to the cut off point of the air governor

Confirm replacement of the granulate cartridge in the maintenance booklet.

Commercially available tools

Number

Designation

WH58.30-Z-1075-06A

Offset screwdriver

Repair materials

Number

Designation

Order number

BR00.45-Z-1014-06A

ATE grease

-