ap4200b4293b

Read out brake wear in display

Type ap · emne 42.00 · version 0100 · 2016-08-12

Gælder for: Model 936.315 with engine 541.976

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 42 Bremsehydraulik og -mekanik › 42.00 Generelt — Serie 936 (modeller 315)

EinPAS 21 bremser/vakuumsystem/trykluftsystem › 21.15 driftsbremse/vakuumsystem › 21.15.5 bremsesystem komplet — Serie 936 (modeller 315)

Gælder også for motorer/gearkasser: 541 976

AP42.00-B-4293B

Read out brake wear in display

28.07.2016

Model

936.315 with engine 541.976

Read out brake wear in display

1

Key

2

Key

3

Key

4

Key

5

Key

6

Key

7

Multi-functional display

N54.30-8274-11

1

Turn ignition key to the drive position

2

Select the "adjustment" menu by repeatedly pressing the key (3 or 4)

3

Select the column over "Setting" menu by repeatedly pressing the key (1 or 2)

4

Press the key (5 or 6) repeatedly until it displays the menu "release diagnosis menu" and release the diagnosis menu by pressing the key (1)

5

Press the key (4) and access the menu "Diagnosis"

6

Select the menu "diagnosis" and confirm by pressing (5)

7

Select the control module by pressing the key (1 or 2) on the control module "FM" and confirm by pressing the key (5)

8

When pressing the key (1 or 2) again, select the menu "measurement values" and confirm by pressing the key (5)

9

When pressing the key (1 or 2) again, read measurement values (MW) MW 2 until MW 5 on multifunction display (7)

Do not actuate the operation brakes during the reading.

10

Register the measurement value on measurement sheet

Axle assignment of brake lining sensors

AH42.10-B-1007-01A

11

Protect vehicle against involuntary movement

12

Release the parking brake

13

Press the key (6) repeatedly until it shows the control module list

14

When pressing the key (1 or 2) again, select the control module "HM" and confirm by pressing the key (5)

15

When pressing the key (1 or 2) again, select the menu "measurement values" and confirm by pressing the key (5)

16

When pressing the key (1 or 2) again, read measurement values MW 2 until MW 5 on multifunction display (7)

17

Register the measurement value on measurement sheet

Axle assignment of brake lining sensors

AH42.10-B-1007-01A

18

By repeatedly pressing key (3 or 4) get back to the main menu

Henviste dokumenter