ap2520b2981xa

Clutch actuation - replace brake fluid

Type ap · emne 25.20 · version 0301 · 2017-09-19

Gælder for: Model 368 with engine 904.973/981, 906.998/999, 924.913/925/995/996, 926.950/996

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 2 Chassis › 25 Kobling › 25.20 Koblingsbetjening — Serie 368 · Serie 904 (modeller 973, 981) · Serie 906 (modeller 998, 999)

EinPAS 17 Drivstreng/aksel › 17.15 Kobling › 17.15.5 koblingsbetjening — Serie 368 · Serie 904 (modeller 973, 981) · Serie 906 (modeller 998, 999)

Gælder også for motorer/gearkasser: 924 913, 924 925, 924 995, 924 996, 926 950, 926 996

AP25.20-B-2981XA

Clutch actuation - replace brake fluid

28.07.2017

Model

368 with engine 904.973/981, 906.998/999, 924.913/925/995/996, 926.950/996

Clutch actuation - replace brake fluid

1

Purging equipment

2

Protective cover

3

Bleeding hose

4

Bleeding valve

B25.20-0019-06

Caution

Risk of poisoning from swallowing brake fluid. Risk of injury from skin and eye contact with brake fluid

Only pour brake fluid into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid.

AS42.50-Z-0001-01A

Brake fluid notes

AH42.50-B-0001-01A

1

Remove the cover of the compensation hydraulic reservoir and remove by suction the brake fluid used

2

Remove protective cover end (2) and connect purging equipment (1)

Observe operation instructions recommended by purging equipment manufacturer (1).

3

Connect purging hose (3) to purging valve (4) and the other side inside the used brake fluid collector container

4

Open the air bleeder (4) until fresh brake fluid comes out the bleeding hose (3)

5

Close the bleeding valve (4), remove the bleeding hose (3) and install the protection cap

6

Disconnect the bleeding equipment (1) from the hydraulic reservoir

Observe operation instructions recommended by purging equipment manufacturer (1).

7

Refuel the compensation hydraulic reservoir up to the specified level and install the reservoir cover

The refueling will be correct when the level is within the maximum (A) and minimum (B) level marks in the reservoir.

8

Check purging valve sealing (4)

Henviste dokumenter