1 | Branch off BN line (1.3) with CLS 1 cockpit ground point cable lug (3) from stationary heater Telestart receiver sub wiring harness (1.1). |
2 | Branch off GN line (1.2) from stationary heater Telestart receiver sub wiring harness (1.1). |
3 | Unpin lines of stationary heater Telestart receiver sub wiring harness (1.1) from 6-pin electrical connector (stationary heater Telestart receiver) (1). |
4 | Cut off contact springs of GN line (1.2), BN line (1.3), OG line (1.4) and RD/YE line (1.6) of stationary heater Telestart receiver sub wiring harness (1.1). |
5 | Attach corresponding contact springs for 12-pin electrical connector (stationary heater Telestart receiver) (1) at GN line (1.2), BN line (1.3), OG line (1.4) and RD/YE line (1.6) of stationary heater Telestart receiver sub wiring harness (1.1). |
6 | Plug GN line (1.2) of stationary heater Telestart receiver sub wiring harness (1.1) into provided 12-pin electrical connector (stationary heater Telestart receiver) at slot 11. |
7 | Plug BN line (1.3) of stationary heater Telestart receiver sub wiring harness (1.1) into provided 12-pin electrical connector (stationary heater Telestart receiver) at slot 1. |
8 | Plug OG line (1.4) of stationary heater Telestart receiver sub wiring harness (1.1) into provided 12-pin electrical connector (stationary heater Telestart receiver) at slot 8. |
9 | Plug RD/YE line (1.6) of stationary heater Telestart receiver sub wiring harness (1.1) into provided 12-pin electrical connector (stationary heater Telestart receiver) at slot 7. |
10 | Cut off fuse box (6) of RD/YE line (1.6) and extend RD/YE line (1.6) with corresponding cable by 0.5 m. |
11 | Cut off contact spring of OG line (1.4) and extend OG line (1.4) with corresponding cable by 1 m. |
12 | Cut off contact spring of GN line (1.2) and extend GN line (1.2) with corresponding cable by 1 m. |
D83.70-1528-06
13 | Attach corresponding contact spring for fuse block 2 (9 fuses) (F55/2) at extended end of RD/YE line (1.6). |
14 | Attach corresponding contact spring for MWH [HLS] electrical connector (X18/56) at extended end of OG line (1.4). |
15 | Attach corresponding contact spring for 10-pin heater booster/stationary heater button electrical connector (2) at extended end of GN line (1.2). |
16 | Prepare 3 m OG line (1.5) with corresponding cable, attach corresponding contact spring for MWH [HLS]/cockpit electrical connector (X18/56) at one end and at other end attach corresponding contact spring for 4-pin hot water auxiliary heater electrical connector (5). |
D83.70-1522-06