AD83.40-S-6001-02A | Diagnostic cable, testing electrical system TM |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Diagnostic cable Open-circuit |
A20.2 7 | |
P11 10 | A90.1 disconnected |
< 5 Ω | Cables Connector X61/6 1.1 |
1.1 | Ground connection |
| P11 |
1 | Ignition: OFF |
< 5 Ω | Cable Ground connection to J200 1.2 |
1.2 | Voltage supply terminal 30 |
| P11 |
3 | Ignition: OFF |
11 - 14 V | Cable Connection to J3 1.3 |
1.3 | Voltage supply terminal 15 |
| P11 |
2 | Ignition: ON |
11 - 14 V | Cable Connection to J32 |