AD80.35-S-6003-10A | Central locking interface, testing electrical system, WSP | Model 638 up to 1.3.99 with code FZ7 (with RRC only) |
| Scope of test | Measuring instrument / Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Interface, central locking - no response (-//-) Model 638 up to 1.3.99 with code FZ7 (with RRC only) | | Ignition: ON Actuations: Unlocking and locking with HHT | Vehicle unlocks and locks according to actuation | 1.1 1.2 Value in order Erase fault memory and perform operational check | ||
1.1 | Interface, central locking CL/CLS/ATA - no response (-//-) | A19.3 15 or A8.1 13 A18.1 1 |
| A25.1 9 A25.1 9 A18.1 2 | Ignition: OFF Couplings of control modules DAS, CL or CLS and ATA detached Bridges inserted in plug A18.1 (with SA ATA only) | < 1 Ω | Cables X131 (up to 30.4.98), X99 (as of 1.5.98) 1.5 Control modules ATA, CL/CLS or DAS (read out ATA and CLS fault memory with HHT) |
1.2 | Interface, central locking CL/CLS - no response (-//-) | A19.3 15 or A8.1 13 |
| A25.1 9 A25.1 9 | Ignition: OFF Couplings of control modules DAS, CL or CLS detached | < 1 Ω | Cables X131 (up to 30.4.98), 1.6 Control modules CL/CLS or WSP/DAS (read out CLS fault memory with HHT) |
1.3 | Interface, central locking CL/CLS/ATA (-//-) | A19.3 15 or A8.1 13 A18.1 1 |
| A25.1 9 A25.1 9 A18.1 2 | Ignition: OFF Couplings of control modules DAS, CL or CLS and ATA detached | < 1 Ω | Cables X131 (up to 30.4.98), Value in order 1.5 |
1.4 | Interface, central locking CL/CLS (-//-) | A19.3 15 or A8.1 13 |
| A25.1 9 A25.1 9 | Ignition: OFF Couplings of control modules DAS and CL or CLS detached | < 1 Ω | Cable X131 (up to 30.4.98), Value in order 1.6 |
1.5 | Interface, central locking CL/CLS/ATA - (CAN and PWM) |
A18.1 1 |
| A25.1 9 A18.1 2 | Ignition: OFF Couplings of control modules DAS, CL or CLS and ATA detached | > 20 kΩ | Cables X131 (up to 30.4.98), Value in order 1.8 |
1.6 | Interface, central locking CL/CLS - (CAN and PWM) |
|
| A25.1 9 | Ignition: OFF Couplings of control modules DAS and CL or CLS detached | > 20 kΩ | Cable X131 (up to 30.4.98), Value in order 1.9 |
1.7 | Interface, central locking + | | Ignition: ON | OFF | 1.8 1.9 Value in order Erase fault memory and perform operational check | ||
1.8 | Interface, central locking CL/CLS/ATA + |
A18.1 1 |
| A25.1 9 A18.1 2 | Ignition: ON Couplings of control modules DAS, CL or CLS and ATA detached | < 1 V | Cables X131 (up to 30.4.98), Control modules ATA, CL/CLS or WSP/DAS (read out ATA and CLS fault memory with HHT) |
1.9 | Interface, central locking CL/CLS + |
|
| A25.1 9 | Ignition: ON Couplings of control modules DAS, CL or CLS detached | < 1 V | Cables X131 (up to 30.4.98), Control modules ATA, CL/CLS or WSP/DAS (read out CLS fault memory with HHT) |