AD80.35-S-6003-08A | DAS control module, testing electrical system, WSP |
| Scope of test | Measuring instrument / Test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | DAS control module (A25) Voltage supply Terminal30 |
| | A25.1 3 | Ignition: OFF |
11-14 V | Fuse (F73 up to 30.4.98, F105f6 as of 1.5.98) Cable Battery Value in order 1.1 |
1.1 | Ground connection |
2 | A25.1 |
3 | Ignition:OFF |
11-14 V | Cable Ground connection (W8 up to 30.4.98, W17.2 as of 1.5.98) Value in order 1.2 |
1.2 | Voltage supply Terminal15 | | Ignition: ON | ON | Fuse (F74 up to 30.4.98, F105f2 up to 28.2.99, and F105f2 on V6 or F105f3 on M111and M611 as of 1.3.99) Cable Relay, terminal 15 (K70) | ||
1.3 | Voltage supply Terminal 15 |
2 | A25.1 |
7 |
Ignition: OFF Ignition: ON |
<1V 11-14 V | Fuse (F74 up to 30.4.98, F105f2 up to 28.2.99, and F105f2 on V6 or F105f3 on M111and M611 as of 1.3.99) Cable Relay, terminal15 (K70) |